16.15 Gerätestatus-Codes - Endress+Hauser Tankvision Tank Scanner NXA820 Handbuch

Beschreibung der gerätefunktionen; bestandsmanagement
Vorschau ausblenden Andere Handbücher für Tankvision Tank Scanner NXA820:
Inhaltsverzeichnis

Werbung

Menü "Systemadministration"
218
16.15 Gerätestatus-Codes
Dier Gerätestatus-Codes sind nur für Servicearbeiten gedacht. Sie sollten nicht für Standard-
vorgänge verwendet werden.
Diagnose-Code
Kurztext
F101
NXA 820 Conn.
Lost
F301
Data Mem. Fault
F302
LAN Fault
F303
SYNC Fault
F304
FPGA Error
F305
NV Data Error
F306
Order Code Error
F307
Expansion Board
Fault
F308
Watchdog Error
F309
FS Security Error
F310
High CPU Load
F311
Low Disk Space
F312
Low RAM
F313
Bad Thread
F314
Reset by WD
F315
CheckSum Error
F316
Language Error
F317
Access Cnfg Err
F318
FPGA Config Err
F319
RTC LowVolt Err
F320
Time Read Err
F321
Time maybe bad!
F322
RTC Nvmgr Err
C324
Archive Export
Started
F325
NAND not
accessible
F326
NAND Write
exceeded
F327
NAND Write stop
exceeded
F328
Database corrupted Configuration database corrupted
Ursache
Unable to Communicate with NXA820
Failed to Detect or Initialize Data Flash
Memory
LAN Cable Disconnected or Failed
SYNC Link Cable Disconnected or Failed
Unable to access FPGA
The data in the NV memory does not match
the RAM copy
The factory set order code is invalid, NXA is
unable to startup
Expansion board type does not match
expected protocol type or failed to program
FPGA
Software Watchdog Error
Security policy compromised due to file-
system error
High CPU Utilization
Low Disk Space
Low RAM
Bad Thread Status
Hardware reset by WatchDog
CheckSum Error
Language Installation Error
Access Configuration Error: No machines
registered for access
fpga.conf file is corrupted or not available
Real Time Clock Battery Low voltage
Detected
Real Time Clock Read Error
Time maintained by the RTC might be
wrong
RTC could not access NV memory to store or
retrive time
NAND Flash damaged
NAND Flash Write operation exceeded
NAND Flash Write operation stop exceeded –
Tankvision
Mögliche Lösung
To reprogram with proper
SREC
The battery might have
drained if the kit was off
for a long duration
Check if i2cdriver started
and working fine
Confirm and set the time
on the kit
Check if nvmanager
started and working fine
Endress+Hauser