Defrosting the cooler

Humidity can form frost in the interior of the cooling device or on the vaporiser. This
reduces the cooling capacity. Defrost the device in good time to avoid this.
A
NOTICE! Danger of damaging the device
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
➤ Take out the contents of the cooling device.
➤ If necessary, place them in another cooling device to keep them cool.
➤ Switch off the device.
➤ Leave the cover open.
➤ Wipe off the defrosted water.
6.12

Replacing the plug fuse (12/24 V)

➤ Replace the defective fuse with a new fuse of the same type and rating.
➤ Proceed as shown (fig. e, page 11).
I
NOTE – Internal DC fuse
There is an additional DC fuse inside the device (Automotive standard
blade fuse, 10 A). This fuse can only be replaced by an authorized repair
center.
6.13

Replacing the light PCB

A
NOTICE! Damage hazard
The lamp can only be replaced by the manufacturer, a service agent or
similarly qualified person to avoid hazard.