General safety notes

2.1 Intended use

The machine is intended for the stripping and crimping
of flexible wires in one work process. Only the material
described below (wires and wire-end ferrules) may be pro-
cessed using the machine.
Process-safe processing can only be guaranteed for Wei-
dmüller wire-end ferrules. The processing of other makes
may lead to faults and damage to the machine.
The machine must only be used within the technical limits
described (see section 3.1). Modifications to and recon-
structions of the machine must not be performed.
Intended use also includes paying attention to the docu-
mentation.
2.2 Material that can be processed and
crimping shape
Wires
Flexible PVC cable H05V-K and H07V-K with a cross sec-
tion of 0.5–2.5 mm²
Wire-end ferrules (WEF)
Models L and LS: Loose Weidmüller wire-end ferrules
(WEF) with plastic collar:
Models L and PZ3
H0,5/14
H0,5/14S
H0,75/14
H0,75/14S
H1,0/14
H1,0/14S
H1,5/14
H1,5/14S
H2,5/14
H2,5/14S
Models LS and LS PZ3
H0,5/12
H0,5/14
H0,75/12
H0,75/14
H1,0/12
H1,0/14
H1,5/12
H1,5/14
H2,5/14
Model LZ: Loose Weidmüller twin wire-end ferrules:
H0,5/14
H0,75/14
H1,0/15
H1,5/16
2518100000/03/06.2017
H0,5/14S
H0,5/16
H0,75/14S
H0,75/16
H1,0/14S
H1,0/16
H1,5/14S
H1,5/16
H2,5/14S
H2,5/16
Model LZ:
Crimp form
Models
L, LS, LZ
Crimp form
Trapezium (standard)

2.3 Safety equipment

The machine is equipped with the following safety devices:
– Safety switch inside on the front plate
– Main valve
– Mains adapter
These items of safety equipment must not be rendered
ineffective. They must be checked once per year by a ser-
vice technician.

2.4 Personnel

Only trained personnel may operate the machine and per-
form maintenance activities. Training also includes having
fully read the operating instructions.
Repairs may only be performed following con-
sultation with Weidmüller Service and only by
an electrical specialist.
Keep the operating instructions stored so that
they can be inspected by operating personnel
at any time.
All documents can also be downloaded from
the Weidmüller website.
L PZ3, LS PZ3
Square (PZ3)
29