Operation

3
Operation
3. 1

Connecting the service terminal ST 220 and putting it into operation

Mains socket
230V / 50 Hz
10
1
1
Service case (ID 142586)
2
MAINS POWER (mains connection, mains fuse, mains
switch)
3
POWER 24V DC ON/OFF switch
4
WINDOW OPEN/CLOSE switch (window/drive)
5
LIN-BUS ON/OFF switch (only for drives with LIN-BUS)
6
Switch ALARM/VENTILATION
(ALARM: Alarm speed, VENTILATION: ventilation
speed)
7
Connection for service terminal ST 220
8
Connection WINDOW (for single drive/window)
Before connection, make sure the DIP switch on the drives (solo/master/slave) is set correctly as otherwise the
X
data will not be able to be read and cannot be changed (refer to the IQ windowdrives wiring diagram).
à Only the master can communicate with the ST 220. If a slave is connected to the ST 220, no text appears on the
display.
à The locking drives Powerlock E 905 and E 906 must be connected to the device in connection with a chain
drive or spindle drive for the data to be read out.
à Drive settings via the service terminal ST 220 can only be made when the drives are in their end positions.
à If drives are connected in a synchro-network, they must be connected to the service case in compliance with
the wiring diagram (see the wiring diagram IQ windowdrives for the circuit diagram).
à A drive must be connected to the IQ box Safety to parameterize it.
20
14
2
9
CURRENT
FUSE24V
WINDOW
POWER 24V
ST220
CHARGE
FULL
POWER 24V
WINDOW
LINBUS
ON
OPEN
ON
ALARM
CLOSE
OFF
OFF
VENTILATION
3
4
5
16
A
B
S
L
or
11
11
8
7
6
13
9
Ammeter (for display of the current consumption of
the drive/window)
10
Mains connection cable
11
Drive connection cable – Service case
12
Service terminal ST 220 (ID 087261)
13
Connection cable ST 220 mini DIN (ID 142581)
14
Drive with LIN-BUS (4-pin flat cable connector)
15
Drive with LIN-BUS (4-wire power supply cable,
3-wire power supply cable with F 1200+)
16
Drive without LIN-BUS (setting parameters not possible)
17
IQ box Safety
18
Connection cable IQ box Safety (ID 193394)
IQ windowdrives
15
17
15
18
A
B
S
L
A
B
or
11
ON
12
X
GEZE
S
L

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Iq box safetySt 220

Inhaltsverzeichnis