Malfunctions

Other malfunctions

If malfunctions have occurred on the fastener driving tool that you
cannot remedy by oiling and cleaning, contact PREBENA Service.
Do not perform any repair work on the fastener driving tool.
Make certain all the malfunctions in the faults have been corrected
by PREBENA Service.

Overview of malfunctions

The overview below shows possible malfunctions and the actions
which must be taken.
Symptom
Fastener driving tool
is losing air.
Operating pressure
too high.
Nails are not being
driven in completely.
38
Possible cause
The fastening screws
have come loose.
A seal is faulty.
Valve faulty.
Operating pressure
is set too high or fastener
driving tool is damaged.
Operating pressure
is too low.
The driver tip on the
fastener driving tool
is worn out.
Remedy
Contact Customer Service
(see page 48).
Contact Customer Service
(see page 48).
Disconnect the fastener
driving tool from the
compressed air supply
immediately.
Contact Customer Service
(see page 48).
Reduce operating pressure.
If the problem persists:
Disconnect the fastener
driving tool from the
compressed air hose
immediately.
Contact Customer Service
(see page 48).
Increase operating
pressure.
Contact Customer Service
(see page 48).