Herunterladen Inhalt Inhalt Diese Seite drucken

tell Compact GSM II Schnell-Installationsanweisung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Configuring reporting to remote monitoring station
1. Enter the receiver phone numbers and the user account ID in the Monitoring
station section.
2. Configure the notifications for each event in the Notifications section as
follows:
 Contact ID code fields: the default event codes belonging to events are
configured by factory. You can change the event codes at will if needed.
 Mon. stat. checkboxes: enable reporting to remote monitoring station.
Configuring the inputs
The 2 contact inputs can be configured in the Inputs section. The inputs can
work in 3 different operating modes: NO, NC, and impulse series detection.
Configuring the relay outputs
The 2 relay outputs can be configured in the Relay outputs section. The relay
outputs are equivalent, i.e. the same parameters can be configured for both
outputs in the Relay 1 and Relay 2 sections. The outputs can work in two
operating modes: bistable and timed (1...9999s), and can be controlled by
different events:
 Input event
 Incoming call
 Temperature event (temperature thresholds for output control can be
configured independently from temperature thresholds used for generating
alarm events)
 Commands sent by SMS (the detailed list of commands is available in the
Installation and Application Manual).
8