Initialization & voltage display:
When the lamp is connected to the battery, the software will run a self test.
All RGB LEDs will flash up and the lamp itself will flash once.
The battery voltage is then indicated by a blue and green LED, as follows:
 The blue LED flashes once for each volt; and then
 the green LED flashes once for each 1/10 of a volt.
To display the battery voltage again, unplug the light from the battery
and then plug it in again.
Example: The blue LED flashes seven times and the green LED then
flashes five times; this means that the measured voltage under load
is 7.5 V. This display helps you assess the actual state of the battery
prior to use.
Interpreting the voltage display:
More than 8.0 V: the battery is fully charged.
7.1 to 7.9 V: the battery needs charging.
6.5 to 7 V: the battery is not ready for use.
Note: To deactivate this display, simply press the button. In other words,
you needn't let the display go through its whole cycle in order to use
the lamp.
The control electronics measures the voltage under load.
Thus, measurements using a voltmeter will not be comparable.
2 2
Switching on:
Press the power switch (doubeclick) to turn the light on; two
blue LEDs will glow, indicating the 22W dimming level. Press
the button rapidly to cycle through other power levels. Refer
to the chart on page 26 for the exact meaning of the five (RGB)
monitor LEDs, as well as instructions for programming options
additional to the factory-set 3-step mode.
Note: The red center LED will only run in a special mode, while
otherwise just the outer 6 LEDs will shine.
Battery voltage
Luminous performance:
(once per Volt)
The ambient temperature and the use of high power levels can reduce power to the LEDs, thus re-
ducing their brightness, to avoid overheating the LEDs and other electronics. The actual reduction is
indicated by the status LEDs: e.g., after a certain period of time, 4 of the 5 blue status LEDs will be lit,
indicating that the power has been reduced from 45W in order to protect the unit from heat damage.
Switching off:
Hold the button down (for more than one second) to switch off the lamp.
Discharged battery capacity:
Battery voltage
(once per 1/10 Volt)
When you shut off the lamp, the discharged battery capacity is shown
via flashing of the blue LED and then the green LED. This information can
only be displayed once as it is deleted when you unplug the battery.
The  blue LED blinks once for each Ah (ampere hour); and then
the  green LED blinks once for each 1/10 of an Ah.
Example: The blue LED flashes once and then the green LED flashes
five times. This indicates that 1.5 Ah have been drawn from the battery.