4.2 Cleaning the valve

Clean the valves (at least) twice a year.
1. Mark the setting of the valve;
2. Remove the valve from the wall or ceiling;
3. Clean the valve in a solution of soap and warm
water;
4. Rinse the valve thoroughly and wipe dry;
5. Place the valve back WITH EXACTLY THE SAME
SETTING (and IN THE SAME HOLE);
6. Repeat this procedure for the other valves.
Some valves have a filter behind it. If a filter is
present clean this in the same way as the valve.
About the valve settings
The ventilation air is supplied and discharged
by means of valves. Gaps under or near doors
in the dwelling ensure that the air flows in the
right direction. In order to ensure that the correct
ventilation volumes are maintained in the rooms, the
following must be observed:
Do not seal the gaps under or near the doors. For
example by furniture, draught excluders or deep-
pile carpet. The gap should be at least 10mm;
Do not change the settings of the valves;
Do not swap the valves around.
The installer will have set all the valves to ensure
the optimum performance of the ventilation system.
Therefore, do not change the setting of the valves.

4.3 Condensation drain

Ensure that the water seal (u-bend) connected to the
domestic waste-water system is always full of water.
EN - 16
4.4 Maintenance by the installer or
maintenance mechanic
Not all neccesary maintenance can be done by
the user.
Once every 2 years the installer or a maintenance
mechanic should come by for the maintenance
inside the balanced ventilation system.
Some installers offer a full maintenance contract
package where the user maintenance can also be
integrated.

5 Malfunctions

In the event of a malfunction, the corresponding
malfunction code will be displayed on the display of
the unit.
In event of a filter malfunction the filter must be
cleaned or replaced as described in the Maintenance
chapter.
In the event of all other malfunction:
1. Note down the malfunction code that appears on
the display of the unit
2. Note down the unit type.
This is given on the identification plate on the unit
near the power supply.
3. Contact the installer or maintenance mechanic
and give him the noted information.
The system should not be disconnected from the
power supply, unless the unit must be taken out of
service due to a serious malfunction, or for filter
cleaning/replacement or any other compelling
reasons.
If the unit is disconnected from the
power supply, mechanical ventilation
of the dwelling will cease. This can
lead to a build-up of moisture and
results in problems with mould.
If the unit is installed in an area with a higher
average humidity (such as bathroom or toilet) the
probability of condensation on the outside of the
unit is high. This is similar to condensation on a
window and no action is needed.