Maintenance schedule

Regular
Before
maintenance
each use
Engine oil
Check
Change
Air filter
Check
Change
Spark plug
Check
Change
Fuel tank
Check
and filter
Change
Valve
Check
clearance
Change
Combustion
chamber
clean
Troubleshooting
The engine does not
start
1. Check fuel level
2. Remove and check the
spark plug
3. User errors
4. Impurities
5. Electrical contact
66
First month
Every 3
or 5
months or 25
operating
operating
hours
hours
*
*
After 200
operating
hours
Possible causes
No more fuel in the tank
Impure gasoline: Engine stored without
care, proper emptying of the tank or filled
with contaminated gasoline
Spark plug defective, dirty, or incorrectly
attached
Spark plug flooded with gasoline
forgotten to operate the brake lever at
start
Fuel filter or carburetor contaminated
When tightening the engine brake lever,
the contact plate at the end of the
Bowden cable does not close
Every 6 months or 50
operating hours
*
*
Troubleshooting
Refill
Empty the tank and the carburetor.
Fill up with new fuel (super unleaded)
Replace the spark plug
Dry and reinstall properly
While the starter is pulled, the upper lever
must be pulled to the handle
Replace or clean the components
Bend back the holder to create the electrical
contact
Once a
Every 2
year or
years or
100
250
operating
operating
hours
hours
*
*
*