Herunterladen Inhalt Inhalt Diese Seite drucken

Leuze ODSL 30 Serie Bedienungsanleitung Seite 25

Optischer abstandssensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Output current
Device-specific data
ODSL 30/V-30M-S12
Electrical data
Switching output, configurable
Analog output, configurable
Error limits
Absolute measurement accuracy
(diffuse reflectance 6% ... 90%,
temperature range 0°C ... +45°C)
Repeatability
(same object,
identical environmental conditions,
measurement object ≥ 50x50 mm
ODSL 30/24-30M-S12
Electrical data
Switching outputs, configurable
Error limits
Absolute measurement accuracy
(diffuse reflectance 6% ... 90%,
temperature range 0°C ... +45°C)
Max. 100 mA per transistor output
1 PNP transistor output, high active
(default)
NPN transistor or push-pull through
configuration
1 voltage output 1 ... 10 V (R
1 current output 4 ... 20 mA
(R
 ≤ 500 Ω)
L
– Measurement range up to 2.5 m:
± 2% without referencing, ± 1%
with referencing
– Measurement range 2.5 m up to
5 m:
± 1.5% without referencing, ± 1%
with referencing
– Measurement range 5 m up to
30 m:
± 1% without referencing, ± 1%
with referencing
± 0.5% of measurement value
2
)
3 PNP transistor outputs, high active
(default)
NPN transistor or push-pull through
configuration
± 5 mm (6% diffuse reflection)
± 2 mm (90% diffuse reflection) after
referencing
EN
 ≥2 kΩ)
L
25

Werbung

Inhaltsverzeichnis
loading