10. For installation in inaccessible false
ceilings or limited space, the connection
piece (B) must be removed inside to con-
nect the exhaust air hose. To do so, first
release the support plate (B) ( with fan mo-
tor ) and push in the hood body (A).
B
Then connect the exhaust air hose and
seal it. Push it back into the hood body (A)
and screw it tight.
30
ASSEMBLY INSTRUCTIONS
The installation is carried out in the reverse order.
11. Insert the cable connector Insert the
filter insert (E) into the hood body (A) and
screw it in place. Close stainless steel front.
12.a) Connect up the
power supply.
12.b)
In
extraction
mode: If using an exter-
nal blower motor, con-
nect
window-contact
and the connecting ca-
ble.
Insert the filter insert
(E) in the hood body (A)
and screw in place.
Close the stainless steel
panel.
13. Carry out a function
test.