INSTALLATION
The appliance can be connected in the following ways:
2 phase connection
2 lives with 2 neutrals connection (2 2N a.c. 230 V /
50 Hz / Cooking circuit): The voltage between live and neutral is
230 V a.c. There may be a voltage of 0 V between the phases if they are
connected to the same phase in the meter cupboard but also 400 V if
they are connected to 2 different phases. Your groups must be fused with
at least 16 A (2x). The connecting power cable must have a minimum
core cross section of 2,5 mm
right zones
ignition transformer/
left zones
2 lives with 1 neutral connection (2 1N a.c. 400 V /
50 Hz): The voltage between the phases and the neutral is 230 V a.c.
Between the lives there is a voltage of 400 V. If there is not a voltage of
400 V between the lives, two wires have been taken from the same live in
the meter cupboard and the hob must be connected with two neutral
wires, as indicated above under 2 lives with 2 neutrals. Install a
connecting bridge between the connection points 4-5. Your groups must
be fused with at least 16 A (2x). The connecting power cable must have a
minimum core cross section of 2,5 mm
right zones
ignition transformer/
left zones
176
electrical connection
.
2
2
.
INSTALLATION
3 phase connection
3 lives with 1 neutral connection (3 1N a.c. 400 V /
50 Hz / Power circuit): The voltage between the phases and the neutral
is 230 V a.c. There is a voltage of 400 V between the lives. Fit a
connecting bridge between the connection points 4-5. Phase 3 carries no
load. Your groups must be fused with at least 16 A (3x). The connecting
power cable must have a minimum core cross section of 2,5 mm
right zones
ignition transformer/
left zones
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c.
Install connecting bridges between the connection points 4-5. Your
groups must be fused with at least 16 A (3x). The connecting power
cable must have a minimum core cross section of 2,5 mm
right zones
ignition transformer/
left zones
electrical connection