GB
Regular maintenance will extend the service life of your high-quality GESIPA
and they should be serviced at least every 2 years by an authorised workshop or by
GESIPA
Service. For tools that are used intensively, we recommend servicing ahead of
®
schedule.
1.10 Storage
The blind rivet setting tool should be stored in a dry place where there is no danger of frost.
1.11 Repairs
Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty
period should only be carried out by skilled technical personnel. Failure to observe the
assembly and setting procedures and operation by non-skilled personnel may result in seri-
ous damage to the blind rivet setting tool. In case of doubt, always send the blind rivet set-
ting tool back to the supplier or to GESIPA
2.
Troubleshooting
2.1
Blind rivet cannot be set
Cause
No battery
Jaws dirty or worn
Jaw assembly loose
2.2
No spent mandrel discharge
Cause
Nosepiece too small
Dirt inside head
Spent mandrel container full
Mandrel tube blocked
22
.
®
Remedy
Charge battery; replace if necessary
Clean them and lubricate or grease the sliding surfaces
or replace them (see 1.9)
Tighten (see 1.9)
Remedy
Exchange according to table (see 1.4)
Clean (see 1.9)
Take off and empty
Remove blocked mandrel and check for free ejection (see 1.9)
tools
®