MOIsT 1
nO
MOIsT 2
nO
OuT TEMP
##.#°C
suPPly w.
##.#°C
rETurn w.
##.#°C
alarM
nO

aPPlICaTIOn InfO

shOw InfO
aPP:
E. 1-zOnE
sw vErsIOn
1.00
sEnsOr 1
ETOG
sEnsOr 2
Off
sEnsOr ETf
Off
ExIT

sETTInGs

Please note that incorrect sensor setup may lead to poor or lacking ice and snow melting.
Press OK and a submenu will be shown on the display.
Select the parameter to be set and press OK.
sETuP
fOrCE hEaT
Off
sElECT sCalE
46
Sensor 1 moisture status. YES / NO / Blank. Blank will be shown if temperature
is above Set Temp or the system is in Afterrun mode.
Sensor 2 moisture status. YES / NO / Blank. Blank will be shown if temperature
is above Set Temp or the system is in Afterrun mode.
Ambient outdoor temperature. Applies only when ETF sensor is connected.
Supply water temperature, hydronic application only.
Return water temperature, hydronic application only.
Fault message, fault type will be displayed. Red LED on front of unit will flash.
Application type: electric or hydronic heating
Software version
Sensor type, sensor 1
Sensor type, sensor 2
Whether an ETF sensor is connected
Return to main menu
Manual start of forced heating. Press OK and select ON to start forced
heating.
The ETO2 controller will provide heat for the pre-programmed afterrun time,
see AFTERRUN 1 and 2.
Whether temperature is to be displayed in Celsius (C) or Fahrenheit (F) can
C
be selected here. Select the required scale and press OK. Press OK to
return to the SETUP menu.