TEChnICal daTa

Thermostat ETO2-4550:
Designed for indoor mounting only!
Supply voltage .... 115/240 V AC ±10%, 50-60 Hz
Supply voltage for ETOG/ETOR
heating (SMPS) ...............................28 V DC, 8 VA
3 output relays
(potential-free contact, NO) .....................3 X 16 A
Alarm relay (potential-free contact, NO) . max. 5 A
Control signal to actuator
(mixing valve) ....................................... 0-10 V DC
Supply voltage to actuator
(mixing valve) ..........max. 48 V AC/DC / max. 2 A
On/off differential ................................ 1.8°F / 1°C
Temperature range ............. -4/+50°F / -20/+10°C
Ambient temperature ............. 32/122°F / 0/+50°C
Ambient air humidity ............................... 10-95%
Enclosure rating ............................................ IP 20
Weight ......................................................... 600 g
Dimensions H/W/D ........................90/156/45 mm
Type ..................................................................1B
Control pollution degree .................................... 2
Rated impulse voltage ................................... 4 kV
Ground sensor - type ETOG-55:
Designed to be embedded in outdoor surfaces.
Detection .....................Moisture and temperature
Mounting .................................. Outdoor surfaces
Enclosure rating ............................................ IP 68
Ambient temperature ...... -57/+158°F / -50/+70°C
Dimensions .....................................H32, Ø60 mm
Ground sensor - ETOG-56/ETOk-1:
Designed to be embedded in outdoor surfaces.
Detection ....................Moisture and temperature
Mounting ................................. Outdoor surfaces
Enclosure rating ............................................ IP 68
4
Ambient temperature ...... -57/+158°F /-50/+70°C
Dimensions, sensor .......................H32, Ø60 mm
Dimensions, tube ........................H78, Ø63.5 mm
Gutter sensor - type ETOr-55:
Designed to be mounted in gutter or downpipe.
Is used together with outdoor sensor type ETF-
744/99.
Detection ................................................ Moisture
Mounting ............................... Gutter or downpipe
Enclosure rating ............................................ IP 68
Ambient temperature ...... -57/+158°F / -50/+70°C
Dimensions H/W/D ........................105/30/13 mm
Outdoor sensor - ETf-744/99:
Detection .......................................... Temperature
Mounting ....................................................... Wall
Enclosure rating ............................................ IP 54
Ambient temperature ...... -57/+158°F / -50/+70°C
Dimensions H/W/D ..........................86/45/35 mm
water pipe sensor - ETf-522:
Detection .......................................... Temperature
Mounting ................................... Strapped to pipe
Enclosure rating ............................................ IP 54
Ambient temperature .... -40/+248°F / -40/+120°C
Dimensions .................................... Ø6.5, L50 mm
NOTE: The snow and ice melting system
is deactivated in the event of sensor
failure - regardless of sensor type.

sEnsOr InsTallaTIOn

Ground sensor - ETOG, figs 1+3:
For installation in outdoor surfaces where ice
and snow are a regular problem. The sensor
must be embedded horizontally with its top flush
with the surrounding surface.
The sensor cable must be installed in
accordance with current regulations.
NOTE: We strongly recommend the use of
cable pipes in order to protect the sensor cable.
Detailed installation instructions are supplied
with the sensor.
With ETOG-55, use the accompanying installation
plate.
With ETOG-56, use the ETOK-1 mounting kit.