Servicing / disassembly

Silence
Thoroughly clean the complete pump and the
drive assembly in regular intervals, at least once a
year. In case of unfavourable conditions, such as
high lime content, a lot of mud or failures, shorter
intervals may be necessary.
Remove the suction housing (1).
Turn the housing locking bar counter-clockwise and
remove (2).
Remove the impeller cover (3) and take out the
drive (4).
Danger of breaking ! The ceramic shaft is
sensitive to impact and rupture, and draws to
the inside due to its magnetic action = snap
effect. For this reason, remove gently.
If the drive unit cannot be moved any more due
to liming or dried soiling, do not use force ! Place
the pump or drive in a diluted vinegar or citric acid
solution for about 24 hours.
Entretien / Démontage
Silence
Nettoyez régulièrement la pompe et l'entraînement
de la pompe, au moins 1 x par an. Lors de conditions
d'utilisation sévères, par ex. une eau très calcaire
ou une forte présence de mucus, nous conseillons
des nettoyages plus fréquents.
Démontez le corps d'aspiration (1).
Retirez le verrouillage de la chambre de turbine en
tournant dans le sens antihoraire (2).
Déposez le couvercle de turbine (3) et retirez
l'entraînement (4).
Attention, risques de bris ! L'axe en céramique
est
sensible
aux
magnétique développe une forte attraction
vers le bloc-moteur. A extraire avec précaution.
Si l'entraînement devait être bloqué en raison d'une
calcification ou d'impuretés sèches : ne pas forcer!
Immergez la pompe ou l'entraînement de pompe
durant env. 24 heures dans une solution à base de
vinaigre.
chocs,
la
puissance
31