10. Troubleshooting guide

Fault
The motor does not
start
The equipment
does not spray, or
only sprays at re-
duced power, even
though the tank
is full
Too much spray
mist
Motor stops sud-
denly
Possible cause
a) Equipment not switched on
b) Connections on motor loose
c) Battery not correctly inserted
a) Nozzle completely or partly clogged
b) The intake fi lter in the tank is completely
or partly soiled
c) The fi lter element in the handle is com-
pletely or partly soiled
d) Liquid too viscous and therefore unsui-
table
a) Distance from object is too great
b) Spray width too great
Battery spent
GB
a) Turn On/Off switch to "I" (see
b) Have the equipment checked
c) Remove battery and reinsert
a) Clean the nozzle (see 7.2)
b) Clean the intake fi lter (see
c) Clean the fi lter element (see
d) Remove liquid, clean equip-
a) Reduce spraying distance
b) Reduce spray width (see
Insert a charged battery (see
5.4)
- 29 -
Remedy
6.)
by a customer service work-
shop
(see 5.4)
section 7.3)
section 7.4)
ment and container (see 7.)