11. Troubleshooting guide

Fault
Motor does not start
Motor performance
drops
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period.
Anl_GC_RT_1440_M_SPK7.indb 21
Anl_GC_RT_1440_M_SPK7.indb 21
GB
Possible causes
- No power at the plug
- Cable defective
- Switch/plug block defective
- Motor terminals or capacitor
disconnected
- excessive working depth
- Soil too hard
- Blades badly worn
- 21 -
Remedy
- Check the power cable and fuse
- Check
- By customer service workshop
- By customer service workshop
- Reduce working depth
- Correct working depth
- Replace hoe blades