Herunterladen Inhalt Inhalt Diese Seite drucken

hanseatic HKGK14349A1W Gebrauchsanleitung Seite 60

Kühl-gefrier-kombination
Vorschau ausblenden Andere Handbücher für HKGK14349A1W:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Page GB-22
Start-up
Space requirement (when the door is open and when the door is closed)
adhesive strips, protective film and foam
padding from the inside, outside and back
of the appliance.
2. Select a suitable location and adhere to
the stipulated minimum distances and
ambient temperatures (see the next
page).
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 1 m3
per 8 g of refrigerant in compliance with the
EN 378 standard.
The amount of refrigerant contained in your
appliance can be found on the data sheet
page GB-31.
The minimum size of the area in which your
appliance is set up is as follows:
Model A1
Model A2
5.75 m³
5.75 m³
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
Model A3
7.2 m³
840

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis