Forcer temperature sensor

WARNING
Overheating of the forcer
High temperatures can cause damage at
the forcer.
Connect the forcer temperature sensor
X
to the drive amplifier or servo controller
at all times.
Ensure sufficient distance and air cir-
X
culation.
A PT1000 temperature sensor is installed in the winding
for temperature monitoring. As the forcer phase tempera-
ture approaches 100°C, the sensor exhibits an increase
in electrical resistance. This change in resistance can be
detected by circuitry within the drive amplifier or servo
controller and used to reduce or disable the output of the
drive amplifier in order to protect the forcer.
1600
1500
1400
1300
1200
1100
1000
900
800
-20
0
Version 02-02-2021
5.10
Zur Temperaturüberwachung ist ein PT1000 Temperatur-
sensor in der Wicklung verbaut. Sobald sich die Tempe-
ratur der Primäreinheit einem Wert von 100°C annähert,
erhöht sich der elektrische Widerstand des Sensors.
Diese Widerstandsänderung kann schaltungsrechnisch
im Antriebsverstärker oder in der Servosteuerung erkannt
werden. Um die Primäreinheit schützen zu können, kann
die Ausgangsleistung entsprechend reduziert oder kom-
plett ausgeschaltet werden.
20
40
60
Temperatur/Temperature (°C)
Servo Tube SA/ SC 38
Primäreinheit Temperatursensor
WARNUNG
Überhitzung der Primäreinheit
Hohe Temperaturen können zu Schäden
an der Primäreinheit führen.
Temperatursensor immer am Antriebs-
X
verstärker oder der Servosteuerung
anschließen.
Sorgen Sie für genügend Abstand und
X
eine ausreichende Luftzirkulation.
80
100
120
140
Page/Seite 29 / 61

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis