Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Control Signals - Balluff BTL5-P1-M Serie Technische Beschreibung, Betriebsanleitung

Micropulse wegaufnehmer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL5-P1-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Transducer - Rod Style
7

Technical Data

Typical values at DC 24 V, room temperature and BTL5 with nominal length 500 mm. Ready for operation at once.
Full accuracy after warm up. Values are with BTL-P-1013-4R, BTL-P-1013-4S or BTL-P-1012-4R magnet rings or
with BTL2-S-6216-8P-Ex, BTL2-S-5113-4K-Ex, BTL2-S-4414-4Z-Ex or BTL2-S-4414-4Z01-Ex floats.
Repeatability
System resolution (BTL5-... + BTA)
depends on processor card or ex-
ternal controller.
Recommended sampling rate when
using one magnet ring:
Nominal length
< 1400 mm
> 1400 mm
Recommended sampling rate for
multiple magnets:
f
Standard
Non-linearity:
Nom. length < 500 mm > 500 mm
±100 µm
Temperature coefficient
(6 µm + 5 ppm * nominal length)/K
Shock loading
100 g/6 ms
per EN 60068-2-27
1
Continuous shock 100 g/2 ms
per EN 60068-2-29
1
Vibration
12 g, 10 to 2000 Hz
per EN 60068-2-6
1
(avoid resonant frequencies of the
transducer rod)
up to 350 bar
Pressure rating
when installed in hydraulic cylinder
(Zone 1)
1
Individual specifications as per
Balluff factory standard
7.1
Dimensions, weights,
ambient conditions
Nominal length
< 4000 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
approx. 2 kg/m
Housing
Stainless steel
Rod
Stainless 1.4571
Diameter
10.2 mm
Wall thickness 2 mm
Module of elasticity
approx. 200 kN/mm
Mounting thread 3/4"-16UNF or
M18×1.5
Operating temp. –40 °C to +60 °C
Humidity < 90 %, non-condensing
Protection class per IEC 60529
IP66, IP67 when closed up
10
english
< 12 µm
7.2

Supply voltage (external)

Regulated supply voltage
BTL5-P1...
Ripple
Current draw < 90 mA (at 1 kHz)
Inrush
f
Polarity reversal protection built-in
Standard
Overvoltage protection
1 kHz
Transzorb diodes
0.5 kHz
Electric strength
GND to housing 500 V DC
250 Hz
7.3

Control signals

INIT pulse
Level
Duration 1 µs (max. 3 µs)
±0.02 % FS
maximum current load for the
RS 485 interface is 20 mA.
7.4

Cable

5 m long, shielded, axial or radial
orientation. Max. length of signal
transmission 500 m
The transducer is
certified with IECEx
PTB 11.0035X. The
current issue can be
found at
www.iecex.com
2
In our accredited EMC Laboratory,
proof has been documented that
these Balluff products meet the
EMC requirements of the following
product standard:
EN 61326-2-3
(noise immunity and emission)
DC 20 to 26 V
< 0,5 V
ss
< 3 A/0.5 ms
+5 V RS 485/422 driver
Maximum permissible
sampling rate f
= 2 kHz
max
For safety reasons the
The
transducer
is certified
under KC
certificate
number 13-
AV4BO-0631.
The CE Mark verifies
that our products meet
the requirements of the
current EMC Directive.
Ignition Class "d"
Flameproof enclosure
7.5

Magnet rings

(order separately)
BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-5
Weight
approx. 10 g
Material
anodized aluminum
Operating temp. –40 °C to +85 °C
7.6
Floats (order separately)
Material
Stainless steel
Operating temp. –20 °C to +120 °C
Float BTL2-S-6216-8P-Ex
Installation dimensions ➥ Fig. 3-7
Weight
69 g
Pressure rated to 15 bar
Float BTL2-S-5113-4K-Ex
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-8
Weight
34 g
Pressure rated to 40 bar
Float BTL2-S-4414-4Z-Ex
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-9
Weight
34 g
Pressure rated to 20 bar
Float BTL2-S-4414-4Z01-Ex
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-10
Weight
52 g
Pressure rated to 20 bar
Emission tests:
RF Emission
EN 55011
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4