Micropulse Transducer in a Flat Profile Housing
6

Technical data

6.1

Accuracy

The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL5-P-3800-2, BTL5-P-4500-1,
BTL5-P-5500-2, BTL6-A-3800-2, BTL6-A-3801-2,
BTL5-F-2814-1S or BTL5-T-2814-1S magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
Repeat accuracy, typical
Sampling rate
Dependent on nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
1)
6.2

Ambient conditions

Operating temperature
Storage temperature
Humidity
Shock rating
Continuous shock
per EN 60068-2-27
3)
Vibration
per EN 60068-2-6
3)
Degree of protection per
IEC 60529 with
screwed-on connector
www.balluff.com
< 10 µm
< 20 µm
250 µs...4 ms
≥ 428 µs
±150 µm
±0.03 % FS
≤ 20 ppm/K
2)
0...+85°C
−40...+100°C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10...2000 Hz
IP67
6.3

Supply voltage

Voltage, stabilized
4)
Ripple
Current draw
(at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength of GND
to housing
6.4

Inputs/outputs

Short circuit resistance
6.5

Dimensions, weights

Housing height
Nominal length
Weight (depends on length) Approx. 1 kg/m
Housing material
Nominal length = 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
2)
level.
Individual specifications as per Balluff factory standard, resonant
3)
frequencies excluded
For
: The transducer must be externally connected via a limited-
4)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
10...30 V DC
≤ 2.5 V
ss
≤ 80 mA
≤ 4 A
Up to 36 V
Up to 36 V (supply cables
only!)
500 V DC
Signal cable to GND
20.8 mm
50...4572 mm
Aluminum
english