BTL5-H1_ _-M_ _ _ _-HC/WC-S94
Micropulse Linear Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1014-2R or BTL-P-1012-4R:
Resolution:
Position > 5 µm
settable over SDO
in steps of 5 µm
Speed
> 0.1 mm/s
settable over SDO
in steps of 0.1 mm/s
Meas. rate f
= 1kHz
standard
Non-linearity
Hysteresis
Repeatability
Temperature coefficient
(6 µm + 5 ppm * nominal length)/K
Shock
100 g/6 ms
per IEC 60068-2-27
1
Continuous shock 100 g/2 ms
1
per IEC 60068-2-29
Vibration
12 g, 10 to 2000 Hz
per IEC 60068-2-6
1
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a
hydraulic cylinder
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weight,
ambient
Nominal length
< 4000 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
ca. 2 kg/m
Housing
anodized aluminum
Pressure tube
Stainless steel 1.4571
diameter
10.2 mm
wall thickness
2 mm
e-modulus
ca. 200 kN/mm
Mounting threads
M18×1.5 or 3/4"-16UNF
Operating temp. –40 °C to +85 °C
Humidity
< 90 %, non-
dewing
Protection rating per IEC 60529
with connector attached:
connector version IP 67
10
english
8.2

Supply voltage (external)

Voltage regulated
BTL5-_ 1...
Ripple
Current draw
Inrush
Polarity reverse protection
built-in
Overvoltage protection
± 30 µm
Transzorb protection diodes
< 1 LSB
Isolation voltage
< 2 LSB
GND to housing 500 V DC
8.3

Signals to Controller

CAN_Low, CAN_High, CAN_GND
corresponding to CiA DS 301
Important notice:
Status changes of each of the
4 cams will be transmitted as
emergency objects with the high-
est priority after < 0.5 ms. Hence,
these transducers are specially
suited for time-critical control
tasks.
2
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 61000-6-4 (emission)
EN 61000-6-2 (noise immunity)
DC 20 to 28 V
24 V + 2 V
pp
< 100 mA
< 3 A/0.5 ms
UL authorization
File No.
E227256
The CE Mark verifies
that our products meet
the requirements of
EU Directive
Emission tests:
RF Emission
EN 55011
Group 1, Class A
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4

Werbung