6.1 Features
Soft-start / soft-stop
●
A soft-start or soft-stop serves to protect the belt winder mech-
anism and the belt.
Obstacle detection
●
If the roller shutter hits an obstacle when it is being lowered,
the RolloTron DECT is switched off. Then it is no longer possible
to operate the device in the same direction again.
> > Run the RolloTron DECT in the opposite direction
and remove the obstacle. Then it is possible to operate
the drive in the original direction again.
There is a risk of injury if the obstacle detection
function is not working.
The belt must be wound on as evenly as possible
●
to ensure safe and correct functioning of the
obstacle detection function.
Please ensure that the belt winds as straight and
●
evenly as possible into the device during its sub-
sequent cycle after the obstacle detection system
has triggered.
Blockage detection / overload cut-off
●
If the drive jams when opening the roller shutter (e.g. due to
ice) the belt winder is switched off.
> > First, remove the cause of the overload.
> > Then it is possible to operate the drive in both directions
again.
Manual operation on site or via the
●
DECT base station (FRITZ!Box)
> > End point setting
> > Manual control (Up/Down/Stop)
> > Set and move to the favourite position
> > Load factory settings
52