Fault
Insufficient water
Crossflow, hot water being
forced into cold water pipe,
or vice versa, when mixer is
closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not
possible
Safety stop button not operating
Diverter stiff
Diverter leaking
English
Cause
Supply pressure inadequate
Regulator filter dirty
Shower filter seal dirty
Backflow preventers dirty or
leaking
Thermostat has not been adju-
sted
Hot water temperature too low
Temperature regulator dirty or
calcified
For new installations: basic
body incorrectly connected
(should be: cold right, hot left)
or installed with 180° rotation
Spring defective
Button calcified
Cartridge damaged
Dirt or sediment on valve seat
Remedy
Check water pressure
Clean filters
Clean filter seal between sho-
wer and hose
Clean backflow preventers,
exchange if necessary
Adjust thermostat
Increase hot water temperature
to 42 °C to 65 °C
Clean temperature regulator,
exchange if necessary
Install function block turned
through 180°
Clean spring and/or button,
exchange if necessary
Exchange diverter
Clean valve seat or exchange
diverter