Herunterladen Inhalt Inhalt Diese Seite drucken

Typenschlüssel Transic111Lp - SICK TRANSIC111LP Betriebsanleitung

Laser-sauerstofftransmitter
Inhaltsverzeichnis

Werbung

11
ANHANG
11.3
Typenschlüssel TRANSIC111LP
SICK TRANSIC Oxygen Transmitter
Version
In-line (range 0 ... 25 vol% O
Ambient environment (range 2 ... 25 vol% O
Sample cell (range 0 ... 25 vol% O
In-line (range 0 ... 100 vol% O
Sample cell (range 0 ... 100 vol% O
In-line (range 0 ... 25 vol% O
In-line (range 0 ... 25 vol% O
In-line (range 0 ... 25 vol% O
In-line (range 0 ... 100 vol% O
In-line (range 0 ... 100 vol% O
In-line (range 0 ... 100 vol% O
[1]
Filter type
Analog output range for oxygen
(can be reconfigured on the field)
Define O
special range
2
Signal output
(can be reconfigured on the field)
Fault state current for analog output
(can be reconfigured on the field)
Relay settings (can be reconfigured on the field)
Setpoint: _______ vol% O
2
Material of sample wetted parts
Mirror Type
Front face coated mirror gold
Front face coated mirror gold
Front face coated mirror gold
Back face coated mirror
Back face coated mirror
Cable bushings
In-line calibration option
Accessories
User's guide language
Calibration
Maintenance and repair
[1] PTFE filter non-compatible for 100 vol% O
[2] Factory default range is 0...25 vol% O
[3] Fault state 3 mA can be chosen only if signal output is 4 ... 20 mA.
[4] Default: 10 vol% O
. Hysteresis: 1 vol% O
2
[5] PTFE filter for calibration gas inlet recommended.
106
B E T R I E B S A N L E I T U N G | TRANSIC111LP
)
with a flange adapter for in-line mounting <0.5bar
2
)
with a wall mounting bracket
2
)
with a sample cell and a wall mounting bracket PN10
2
)
with a flange adapter for in-line mounting <0.5bar
2
)
with a sample cell and a wall mounting bracket PN10
2
)
with a flange adapter for in-line mounting PN10
2
)
with a weld adapter for in-line mounting PN10
2
)
with a 3" clamp adapter for in-line mounting PN10
2
)
with a flange adapter for in-line mounting PN10
2
)
with a weld adapter for in-line mounting PN10
2
)
with a 3" clamp adapter for in-line mounting PN10
2
No filter (sample cell installation)
Stainless steel net (1.4404)
PTFE filter with stainless steel net (1.4404)
O
(0 ... 5 vol%)
2
O
(0 ... 10 vol%)
2
O
(0 ... 15 vol%)
2
O
(0 ... 20 vol%)
2
O
(0 ... 25 vol%)
2
O
(0 ... 100 vol%)
2
[2]
from _______vol% O
4 ... 20 mA
0 ... 20 mA
[3]
≤ 3 mA
≥ 21 mA
[4]
Digital output opens ONLY when fault state occurs
Digital output opens when O2 value decreases below setpoint
Digital output opens when O2 value increases above setpoint
Digital output opens to indicate request for maintenance
Gasket material
EPDM
FFKM Original Kalrez® Spectrum
FKM with BAM-Approval
FFKM Original Kalrez® Spectrum
FKM with BAM-Approval
Cable gland M20x1.5 (cable diameter 8... 11 mm)
Conduit fitting NPT1/2" (inner threads)
Connector (8 pin M12 male) with 2 m cable
Connector (8 pin M12 male) with 5 m cable
Connector (8 pin M12 male) with 10 m cable
no
Calibration gas inlet with check valve
None
RS232 service interface cable for PC
English
German
Spanish
Russian
French
Italian
Chinese
Portuguese
ISO 9001 compliant factory calibration
Standard maintenance and repair
. PTFE filter for wet gases near dew point not recommended.
2
.
2
.
2
TRANSIC111LP-
to _______vol% O
2
2
[5]
Beispiel: TRANSIC111LP- A 2 B 1 A 1 A 1 A 1 A 1 A
A
B
C
D
E
F
G
H
I
J
K
1
2
3
A
B
C
D
E
K
X
1
2
A
B
1
X
Y
4
A
B
C
F
G
1
2
3
4
5
A
B
1
2
B
C
D
E
F
G
H
I
1
8014083/ZWT7/V3-1/2020-06 | SICK
Irrtümer und Änderungen vorbehalten
A

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis