ACCESSORIES FITTING
·
The inflator is supplied with the standard tapered fittings, that are located in the carry bag.
·
Chose the correct inflation valve fitting from the supplied fittings kit.
·
During inflation/deflation the valve must be kept open by a suitable adaptor. Adaptors with
inner cross bars are recommended for use with electrical inflators.
Optional bayonet adaptors are offered in Scoprega catalogue.
·
Make sure that the main switch is set on OFF.
·
Take the inflation hose from the bag.
·
Connect the inflation hose to the inflation port (OUT) or to the deflation port (IN).
·
Install the chosen inflation valve fitting.
·
Fit the adaptor onto the inflation valve.
OPERATING THE INFLATOR
·
Connect the clips to the battery terminals.
·
Always stretch the electric cable.
·
Set the desired pressure value (between 175 and 250 mbar).
To deflate set the pressure value on 175 mbar.
·
Switch the ON/OFF button ON.
·
Press the START button.
·
When inflating, the pump switches off automatically when the set pressure is reached.
WARNING
Make sure polarity is correct (red is positive).
Otherwise the inflator WILL NOT START.
WARNING
When connecting the cable to the battery, make sureto avoid short circuits and possible
fire risk.
WARNING
Check the proper voltage. Do not operate a 12V inflator with a 24V battery.
WARNING
Don't leave the inflator running unattended. Over-inflation could result in serious injury and
property damage.
WARNING
Check the recommended maximum pressure to avoid risk of bursting.