Table 3: Charger LED Indicator (Continued)
Waiting to Rapid Charge
•
Amber
Slow Flash
•
•
•
Battery
Under-Voltage
Recovery
Battery too Cold,
Temperature <
approximately 5°C (or
value programmed in
battery)
Battery too Hot,
Temperature ≥
approximately 45°C
(or value programmed
in battery)
Thermistor short to
Battery (+)
Upon completion of
Under-Voltage Recovery,
once a cold battery warms up
or once a hot battery cools
down, the charger
automatically transition to
Charging.
If Waiting to Rapid Charge
continues (e.g., more than
30 minutes), then remove the
battery. Inspect the charger
and battery contacts to ensure
they are clean. Reinsert the
battery.
9