CalIBraTION
(only installation technicians)
MaIN lIFT CalIBraTION
1. Turn the lift off.
2. Set dip switch 5 to ON
3. Turn the lift on
4. Wait 2 seconds then set dip switch 5 to OFF.
5. Move the lift to the CAL 0 point (lowered completely to the floor), then press the
button on the board.
6. Move the lift to the CAL1 point (first tooth from bottom), then press the button on
the board.
7. Move the lift to the CAL2 point (last tooth at the top), then press the button on the board.
8. Wait for the message "CALIBRATION OK", then turn the lift off. The main lift is now
calibrated.