Single unit operation

3.2.1

Basic configuration (Local Sense)

± SENSE have to be connected to the RFE2500 ± Local SENSE terminals prior to operating the supply.
ENABLE input must be connected to SIGNAL RETURN in order for the supply to turn on.
3.2.2

Basic configuration (Remote Sense)

± SENSE have to be connected to the ±V terminals on the Load side prior to operating the supply.
ENABLE input must be connected to SIGNAL RETURN in order for the supply to turn on.
1. Maximum voltage drop on load connection:
RFE2500-12: 0.25V/wire; RFE2500-24: 0.5V/wire; RFE2500-48: 1V/wire.
2. Twisted wires should be used for Remote Sensing connection.
3. If Remote Sensing is used, do not break Main Output connection.
+V
+SENSE
J1-2
LOCAL +SENSE
J1-12
LOCAL -SENSE
J1-11
-SENSE
J1-1
-V
ENABLE
J1-9
SIGNAL RETURN J1-19
VOLTAGE PROG. J1-3
TRIM
J1-13
Figure 3–2: Local Sense Connection
+SENSE
J1-2
-SENSE
J1-1
-V
ENABLE
J1-9
SIGNAL RETURN
J1-19
VOLTAGE PROG.
J1-3
TRIM
J1-13
Figure 3–3: Remote Sense Connection
ATTENTION:
+V
-V
+V
-V
12
LOAD