Herunterladen Inhalt Inhalt Diese Seite drucken

Install The Installation Plate On The Wall; Indoor Side Tubing - Panasonic S-36PK2E5B Einbauanleitung

Vorschau ausblenden Andere Handbücher für S-36PK2E5B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 75
(2) Before making the hole, check carefully that no studs or
pipes are directly run behind the spot to be cut.
Avoid areas where electrical wiring is
CAUTION
located.
The above precautions are also applicable if tubing goes
through the wall in any other location.
(3) Using a sabre saw, keyhole saw or hole-cutting drill
attachment, cut a hole of ø80 mm in the wall. Hole should
be made at a slight downward slant to the outdoor side.
Indoor
side
Hole Dia. (mm)
(4) Place a plastic cover over the end of the pipe (for indoor
side only) and insert the pipe in the wall.
This will protect the tube from contacting the metal lath or
wire lath, leakage due to condensation or entering small
animals through the hole.
CAUTION
When the wall is hollow, please be sure to use the Piping
sleeve assembly to prevent dangers caused by mice biting the
connection cable.
Wall
Indoor
Outdoor
Sleeve for tube
assembly
ø80 mm
through hole
Putty or caulking compound
Wall
Outdoor
side
Cut a hole.
80
15 mm
Approx. 5 - 7 mm
Bushing for tube
Assembly

3-3. Install the Installation Plate on the Wall

If Wooden Wall
(1) Attach the installation plate to the wall with the 5 screws
(4 × 20) provided.
(2) Double check with a carpenter's level or tape measure
that the panel is level. This is important to install the unit
properly.
(3) Make sure the panel is flush against the wall. Any space
between the wall and unit will cause noise and vibration.
If Concrete Wall
(1) When attaching the installation plate to the concrete wall,
use the screws (field supply) for concrete or an optional
anchor plug and fix to the hole of ø5 mm of the installation
plate as shown in the figure under the section 3-2.
When fixing with bolt, attach to the hole of ø8 mm.
(2) Double check with a carpenter's level or tape measure
that the plate is level. This is important to install the unit
properly.
(3) Make sure the installation plate is flush against the wall.
Any space between the wall and unit will cause noise and
vibration.

3-4. Indoor Side Tubing

Arrangement of tubing by direction
1) Left side, left bottom or right side, right bottom tubing
Cut out the corner of the right/left frame with a hacksaw or
the like.
Grille
Left tubing
outlet
2) Right-rear or left-rear tubing
In this case, the corner of the frame need not be cut.
10
Grille
Right tubing
outlet

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis