TRANSPORT, STRORAGE & CLEANING / REGULAR CHECKS
10. TRANSPORT, STORAGE & CLEANING
The textile materials of our products consist of PA or PES. The fitting parts consist of aluminum and
steel. The heat load must therefore never exceed 100°C. Chemicals may attack the material and
cause it to lose in strength. In case of reactions such as discoloration or hardening, the product must
be retired for safety's sake.
The products much always be transported in suitable packaging (protected from dirt, moisture, chem-
icals, UV radiation, mechanical damage, etc.).
Conditions of storage:
• Protected from light (UV radiation, welding machines ...) dry and clean at room temperature
• Not in the proximity of chemicals (acids, lyes, liquids, vapours, gases, ...) and other aggressive environments
• Protected against sharp-edged objects
For cleaning, use lukewarm water and mild-action detergents. Then, rinse the equipment with clear
water and dry it prior to putting it into storage. Dry the product in a natural way, not near fires or other
heat sources.
For disinfection, use only substances that do not have an impact on the synthetic material and met-
als used.
If you fail to observe these provisions, you will be putting yourself into danger!

11. REGULAR CHECKS

Checking the equipment at regular intervals is absolutely necessary: your safety depends on the
effectiveness and durability of the equipment!
Prior to and after any use, the equipment should be checked for wear or damage.
Also check it for the legibility of the product labelling! The use of damaged components or compo-
nents subjected to a fall must be discontinued at once. If there is only the slightest doubt, the product
needs to be retired or subjected to testing and by a competent person.
When using the equipment in occupational health and safety to EN 365, it must be checked at
least every 12 months by a duly qualified person strictly observing the instructions, or else by the
manufacturer, and it must, whenever necessary, be replaced. These inspections must be documented
(documentation of equipment; cf. attached Inspection Sheet). Refer to national regulations for inspec-
tion intervals.
Here, too, if there is the slightest doubt, the product must be withdrawn or inspected by an expert