Herunterladen Inhalt Inhalt Diese Seite drucken

Schüco IPE 030 CN 05 Kurzanleitung Seite 71

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
Networking of Schüco inver-
ters via CAN bus
IPE 030 - 033 CN 05
CAN
Pin
Description
3
CAN_H
4
CAN_L_T
5
CAN_H_T
6
CANL
7
CAN_SHLD
8
N.C.
Schüco inverters can be networked with each other via the CAN bus interface. Use
the included Ethernet cable to network the Schüco inverters with each other. Con-
nect a terminating resistor at the first and last Schüco inverter in the series. The plug-
gable terminating resistors are contained in the delivery scope.
1
1 Terminating resistor connector
The overall length of the CAN bus network depends on the selected bitrate. The fol-
lowing table shows the possible bitrates and resulting bus lengths.
Schüco inverters are provided with a default setting of 125 kbit/s as standard.
Bitrate
Bus length
100 kbit/s
650 m
125 kbit/s
500 m
250 kbit/s
250 m
500 kbit/s
100 m
Meaning
Description
Bus line (dominant
<3
high)
Termination
-4
Termination
-5
Bus line (dominant
<6
low)
Optional CAN
<7
shield
<8
Installation
modem
Meaning
RXh
VCC
GND
RXI
R1h
R1I
1
67

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ipe 033 cn 05

Inhaltsverzeichnis