6.8.2 ACOUSTIC ALARM IN CORRESPONDENCE OF THE HI-OK-LO LIMITS

One can decide if the acoustic alarm should enable when the "OK" symbol is on or when the "HI" or "LO" symbols are
on. To choose the alarm enabling mode, see step "bEEP", section 7.1.

6.8.3 VISUAL INDICATION OF THE WEIGHT CHECK

Put a weight on the plate of the scale.
The indication symbols will enable depending on which thresholds have been configured:
WITH BOTH THRESHOLDS CONFIGURED
-
The HI symbol of the LCD display will turn on when the detected weight exceeds the UPPER THRESHOLD.
-
The OK symbol of the LCD display will turn on when the detected weight is between the LOWER THRESHOLD
and the UPPER WEIGHT THRESHOLD.
-
The LO symbol of the LCD display will turn on when the detected weight is less than the LOWER THRESHOLD.
WITH THE UPPER THRESHOLD CONFIGURED AND THE LOWER THRESHOLD = 0
-
The OK symbol of the LCD display will turn on when the detected weight exceeds the UPPER THRESHOLD.
-
The LO symbol of the LCD display will turn on when the detected weight is less than the UPPER THRESHOLD.
WITH THE UPPER THRESHOLD = 0 AND THE LOWER THRESHOLD CONFIGURED
-
The HI symbol of the LCD display will turn on when the detected weight exceeds the LOWER THRESHOLD.
-
The OK symbol of the LCD display will turn on when the detected weight is less than the LOWER THRESHOLD.
NOTES
-
The weight check function is enabled when the limit values are entered. To disable the function one should set the
limit values at zero.
-
The function is not valid when one enters a lower limit greater than the upper limit.
-
The weight check is enabled with a weight greater than the minimum weight (20d).

6.9 UNIT OF MEASURE CONVERSION

By pressing various times the U key the conversion into the configured secondary units of measure takes place (see
"Unit" step, section 7.4); the relative symbol will turn on in the display (see section 5).
NOTE:
- The function is not available if the counting function or the percentile function is enabled.
- With APPROVED instrument the weight in secondary units is displayed for 5 seconds, after which the display goes
to the scale unit of measure.

6.10 FUNCTION OF AUTOMATIC TURN-OFF

The scale is fitted of a programmable automatic turn-off function, which allows to save energy in case of not using it
temporarily; the automatic turn-off starts functioning when the scale is unloaded (gross weight = 0) for the time (in
minutes) programmed in oF step.
The values vary among:
00 DISABLED
03 3 minutes
05 5 minutes
15 15 minutes
30 30 minutes

6.11 VISUALISATION WITH SENSITIVITY TIMES 10

It's possible to use this function as a test in the calibration phase.
Keep the TARE key pressed for three seconds and release: the display will show the weight with the minimum division
times 10 (a blinking digit is added).
After about 5 seconds the display will return in the standard mode.