7. SET-UP ENVIRONMENT

The scale has various parameters that can be configured in the SET-UP environment.
Enter in the SET-UP environment press F and M+ simultaneously at start-up.
- The display will show the first function, which is "inC":
- Use TARE or set a value, using the % key and the +/- key to move the active digit, and then using the TARE key to
increment a digit
- Press the ZERO key to confirm the modification and pass to the following step.
- Press the % key to pass to the previous step or the +/- key to pass to the following step without confirming the
modification.
- To exit from the set-up, press the ZERO key on the "RETURN" step or the C key on any step.

7.1 SET-UP ENVIRONMENT BLOCK DIAGRAM

SETUP
ENVIRONMENT
In the parameter description:
- The METRIC parameters are shown with the (*) symbol, and, with approved instrument, these are read only. See
section 11.
r 3000, r 6000,
inC (*)
EL on, EL AU,
EL
AU
AU oFF,
b600, b1200,
baud
b2400, b4800,
printer
tP, LP-50
ACC on,
ACC
units
AZ 0.5d,
AZ (*)
AZ 1d, AZ 2d,
bEEP
SPEEd
7.5, 15, 30, 60
oF
0, 3, 5, 15, 30
return
r dual
EL oFF,
AU on,
P Cont
b9600
ACC oF
g
Ut on, Ut oFF
lb
Ut on, Ut oFF
AZ 4d
bEEP 0,
bEEP 1,
bEEP 2
12

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Awm3Awm6Awm15Awm30

Inhaltsverzeichnis