Scale House AWM Serie Bedienungshandbuch Seite 13

Multifunktions-/zählwaage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

inC
SCALE DIVISIONS (*)
By pressing TARE one selects one of the scale divisions:
Value
Divisions
3000
3000
6000
6000
dUAL
3000 + 3000
EL DISPLAY BACKLIGHTING
EL oFF backlighting always off
EL on
backlighting always on.
EL AU
backlighting on only when the weight is greater than 20d or when a key is pressed. When a key is pressed,
if the weight is less than 20d, the backlighting remains active for 5 seconds.
AU
SETTING MANUAL OR AUTOMATIC TOTALISATION
The accumulation operation, normally done manually through the M+ key, can be made automatically when the weight
stability is reached. The choice of the execution mode of the totalisation is executed in this parameter.
Press TARE to select one of the suggested values:
AU on
Automatically upon weight stability.
AU oFF Manually through the M+ key.
P Cont Not used in this application.
baud
NOT USED IN THIS APPLICATION
Press M+ to pass to the following step
Printer NOT USED IN THIS APPLICATION
Press M+ to pass to the following step
ACC
ENABLING THE TOTALISATION FUNCTION
By pressing TARE one enables (on) or disables (oFF) the weight totalisation function.
units
CONFIGURATION OF SECONDARY UNITS OF MEASURE
By pressing TARE it's possible to choose the units of measure for the conversion function (see section 6.9), enabling
(on) or disabling (oFF) the suggested secondary units of measure:
1) The display proposes the first secondary unit of measure to be enabled or disabled.
2) Press TARE to change the options and confirm with ZERO, or press M+ to exit without confirming and pass to the
following unit.
3) The display proposes the 2nd secondary unit to be enabled or disabled.
4) Proceed as described in point 2 up until the last proposed unit of measure.
AZ ZERO TRACKING (*)
By pressing TARE one sets the divisions' number for the zero tracking, in other words, scale's thermal drift
compensation parameter; the set value corresponds to the number of divisions which is cleared.
Select one of the suggested divisions: 0.5d, 1d, 2d, 4d.
bEEP
ACOUSTIC ALARM
bEEP 0
acoustic alarm disabled
bEEP 1
active acoustic signal with active "OK" symbol.
bEEP 2
active acoustic signal with active "HI" or "LO" symbol.
SPEED SETTING ADC CONVERTER READING SPEED
By pressing TARE one select the reading speed of the ADC converter; the set value corresponds to the number of
readings made in a second.
Select one of the suggested reading speeds: 7.5, 15, 30, 60.
13