Indication of measuring unit on display
0 * Without measuring unit
1
m
2
dm
3
cm
4
mm
5
L
Assignment of lower display
The upper display always indicates the current value.
0
Without lower display
1
P1 - Preset
2 * P2 - Preset
3
SC - Start count
4
tot - Totalizer
5
b - Batch counter
6
SF - Scaling factor
Counting mode main counter and totalizer
0 * Counting input track A, reversal track B
1
Subtraction track A adding and track B subtracting (A-B)
2
Totaling track A adding and track B adding (A+B)
3
Track A 90° track B single evaluation
4
Track A 90° track B double evaluation
5
Track A 90° track B quadruple evaluation
In case of the counting mode „track A 90° track B" , the frequency of
track A and B (Line 31 and 32) must be adjusted to 10 kHz.
Frequency main counter track A
0 * 10 kHz
1
25 Hz
2
3 Hz
Frequency main counter track B
0 * 10 kHz
1
25 Hz
2
3 Hz
Input logic and operating thresholds of signal inputs
0 * PNP Operating threshold 6 V
1
NPN Operating threshold 6 V, or for Namur w/o ex. protection
2
PNP Operating threshold 3 V
3
NPN Operating threshold 3 V
Function control input 1 (contact 9)
0 * PC - Main counter - Reset static
1
PC - Main counter - Reset edge-triggered
2
PC - Main counter - Stop
3
Hold
4
Programming disabled
5
Keylock
6
Print (principally, 30 ms minimum pulse duration)
7
Main counter-outputs ON
8
Main counter-outputs OFF