Modify status Enter corresponding status number via the keys
Programming field 1
Here it is possible to select and modify all operation parameters. The
operation parameters that are disabled for the operator are also dis-
played.
PC - Main counter (current counter)
P1 - Preset value 1
P2 - Preset value 2
SC - Start count
tot - Totalizer
b - Batch counter
SF - Scaling factor
The dash line indicates the end of the first programming field.
Switch to programming field 2 by pushing
Programming field 2
The individual operation parameters for operator access are disabled
or enabled here.
● „Stat" appears on the upper display. The lower display indicates
the line number and the abbreviation for the operation parameter.
The status number is entered on the upper display.
Meaning of the status numbers
It is possible to select, read and modify the operation para-
0
meter on the operator level. (free access)
1
It is possible to select and read the operation parameter on
the operator level. (display only)
2
It is impossible to select the operation parameter on the
operator level. It is corresponding function is however
sustained. (disabled)
Factory setting is always marked with a *.
Press
key.
www.baumer.com
NE134
or
.
.
35