Herunterladen Inhalt Inhalt Diese Seite drucken

ABB ACS880-34 Sicherheitsvorschriften Seite 9

Frequenzumrichtermodule für benutzerdefinierte schrankinstallationen
Vorschau ausblenden Andere Handbücher für ACS880-34:
Inhaltsverzeichnis

Werbung

The Safe torque off function
WARNING!
The drive cannot detect or memorize any changes in the STO circuitry when the
drive control unit is not powered. If both STO circuits are closed and a level-type
start signal is active when the power is restored, it is possible that the drive starts
without a fresh start command. Take this into account in the risk assessment of
the system.
CHANGED
Frame
SIL/
PL
size
SILCL
R11
3
e
Filters
CHANGED
ACS880-34-...
du/dt filter type
U
= 400 V
n
505A-3
FOCH0610-7x
585A-3
FOCH0610-7x
650A-3
FOCH0610-7x
ACS880-34-...
Sine filter type
U
= 400 V
n
505A-3
NSIN0900-6
585A-3
NSIN0900-6
650A-3
NSIN0900-6
Filter type
NSIN0485-6
NSIN0900-6
PFH
PFD
avg
SFF
(T
= 20
1
(T
= 2
a)
1
(%)
a)
(1/h)
99.65
3.65E-
3.20E-
09
05
ACS880-34-...
U
= 500 V
n
414A-5
460A-5
503A-5
ACS880-34-...
U
= 500 V
n
414A-5
460A-5
503A-5
PFD
avg
MTTF
DC
D
(T
= 5
1
(a)
(%)
a)
8.00E-
18327
≥90
05
du/dt filter type
ACS880-34-...
FOCH0320-5x
330A-7
FOCH0320-5x
370A-7
FOCH0610-7x
430A-7
Sine filter type
ACS880-34-...
330A-7
B84143V0390S229
NSIN0485-6
370A-7
NSIN0900-6
430A-7
ABB ordering code
64254936
64254961
Update notice 5
T
M
Cat.
SC
HFT
CCF
(a)
3
3
1
80
20
du/dt filter type
U
= 690 V
n
FOCH0610-7x
FOCH0610-7x
FOCH0610-7x
Sine filter type
U
= 690 V
n
NSIN0485-6
NSIN0485-6
NSIN0485-6