Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Assembly - Bosch Rexroth WSC60GK Betriebsanleitung

Schweißkoffer/hängeanlage/standgehäuse
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

58/73
Bosch Rexroth AG
General notes for property damages and product damages
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
3.2

Installation and assembly

Metal burrs from drilling and sawing work
Possibility of short-circuits, damage to electrical equipment, unexpected
plant reactions!
All affected components in the switch cabinet should be well partitioned
prior to all work!
Non-compliance will result in the extinction of any warranty claims.
Remove all metal burrs carefully after work.
Water leakage while connecting cooling water lines
Possibility of damage to the electrical equipment, unexpected
plant reactions!
All affected components in the switch cabinet should be well partitioned
prior to all work!
Non-compliance will result in the extinction of any warranty claims.
Remove residual moisture carefully after work.
Leakage in the cooling fluid circuit
Possibility of damage to the electrical equipment, unexpected
plant reactions!
Install the water-cooled modules so that the units inside the switch
cabinet are sufficiently protected against leaking cooling water.
Heat accumulation caused by insufficient clearance
Possibility of temporary interruption of the welding process, a reduced
useful life of the product, destruction of the device, damage
to the electrical equipment, unexpected plant reactions!
Make sure that an installation clearance of at least 100 mm remains
above or below the ventilation slots of the product.