7 Troubleshooting

The following overview helps find possible faults and
their causes and perform measures to rectify the
faults.
Fault
Cause
The balancer does
The cable pull in the
not hold the weight
balancer is not
of the tool.
correctly adjusted or
is defective.
The tool cannot be
pulled down.
The tool does not
The cable on the
work.
overhead suspension
is disconnected.
The cable tie reel will
The cable tie reel is
not unwind.
inserted in the wrong
winding direction
(counterclockwise)

8 Maintenance

DANGER
Danger of lethal electric shock!
There is a risk of lethal injury when touching live
components.
f Switch off the power supply unit before taking out of
operation
f Pull the power cable out of the socket.

8 .1 Cleaning

NOTE
Possible material damage due to unsuitable cleaning
agents!
Incompatible and aggressive cleaning agents can damage
surfaces or components.
f Only use cleaning agents that are compatible with the
surfaces and materials of the overhead suspension,
tool, power supply unit, and cables.
f Cover sensitive components for protection.

8 .1 .1 Cleaning the overhead suspension

1 Disconnect the power supply unit.
2 Clean dirt and foreign objects off of the overhead
suspension.
; The overhead suspension is cleaned.
Operating Instructions • Overhead Suspension AT2000 CPK • 03/2020 • 106-29021
8 .2 Maintenance

8 .2 .1 Important information

The overhead suspension must be regularly
maintained to ensure it is working safely.
Remedy

8 .2 .2 General maintenance measures

f The balancer must
be correctly
adjusted.
à „Adjusting the
balancer (cable
pull)" on
page 9
f Check the overhead suspension regularly to ensure it
is working properly.
f The balancer must
be replaced.
f Check the suitability of the workplace.
f Connect and
f Check the fastened electrical cords for damage.
fasten the cable
f Damaged electrical cords must be replaced
properly.
immediately by qualified maintenance personnel.
f Insert the cable tie
reel with

8 .3 Repair

clockwise winding
direction.
Severe injuries due to improperly performed
maintenance work!
Maintenance work not carried out correctly can affect the
safety of the overhead suspension and result in severe
injuries.
f Maintenance work should only be performed by
NOTE
Material damage due to improperly performed
maintenance work!
Maintenance work not carried out correctly can damage
the overhead suspension and result in failures.
f Maintenance work should only be performed by
The maintenance required for the tool and the power
supply unit is described in the tool's operating
instructions.