5.2 Temperature 1 regulation for slot 1 (water heating)

5.2.1 Adjusting the temperature 1 (water heating) value

When "P01" is flashing, press
(P01 to P02 can be selected using ▲ and ▼)
When "CHA" is flashing, the ▲ and ▼ buttons can be used to select 'CHA' (change) or 'dEL' (delete).
If "CHA" is selected, press
Use the ▲ and ▼ buttons to set the hours between 0 and 23.
button, the minutes digits "00" will flash.
Press the
Use the ▲ and ▼ buttons to set the minutes between 0 and 59.
button, the desired temperature value will flash - "25.0".
Press the
Use the ▲ and ▼ buttons to set the desired temperature value between 0 and 40.
Press and hold the
Note: It is not possible to enter turn-off times. The start time of P02 is the end time of P01. If only P01 is set, the pro-
grammed levels are maintained over 24 hour. It is advisable to program two time periods to differentiate day values
and night values.
Attention: If two times for the start of temperature control are identical, the error E3 appears on the display.

5.2.2 Alarm setting temperature 1 (water heating)

When "00" flashes, use the ▲ and ▼ buttons to set the +/- alarm between 1 and 5° C.
"00" means that no alarm is set.
Press
to program position 1.
to confirm, the hours "00" will flash.