Herunterladen Inhalt Inhalt Diese Seite drucken

Approved By; Tt80 Serie Has Been Tested And Approved By The Following Standards; Technical Specifications - TermaTech TT80RL Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TT80RL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16

10.0 Approved by:

TEKNOLOGICAL INSTITUT, Energy and climate
Renewable Energy and Transport
Kongsvang Allé 29
8000 Aarhus C
www.teknologisk.dk
10.1 TT80 Series has been tested and approved by the following standards:
CE - EN13240 (EU)
DIN+ (Germany)
15A (Austria)
NS3058, 3059 (Norway)
AEA (UK)

11.0 Technical specifications:

Type
Nominal output:
Height:
Width:
Depth:
Weigt approx.:
Width of combustion chamber:
Smoke nozzle diameter: 150mm
Average values for testing TT80:
Exhaust gas temperature 245°C
Exhaust gas mass flow 5,3 g/s
Efficiency 81%
Flue draught 12 Pa
38
TT80RL
TT80RLS
5,5kW
5,5kW
1005mm
1005mm
560mm
629mm
372mm
372mm
143kg
171kg
420mm
420mm

Werbung