Herunterladen Inhalt Inhalt Diese Seite drucken

Steinbach Poolrunner S63 Originalbetriebsanleitung Seite 44

Vorschau ausblenden Andere Handbücher für Poolrunner S63:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Fault description
The device does not function.
The device does not function
and all indicators are lit.
The device does not sink.
The device does not clean
optimally.
The device floats up or turns in
a circle on the bottom of the
pool.
If the problem cannot be solved, contact the customer service listed on the last page.
44
Cause
The control unit is not
completely plugged in.
The control unit needs a
different voltage than the local
one.
Too much air in the housing.
There are foreign objects in
the drive.
The device has a fault.
There is air in the device.
The device swirls up dirt and
does not clean sufficiently.
Too much air in the housing.
The salt content is too high
and the device has more
buoyancy.
Remedy
Check the plug connection of
the power cable and the
control unit.
Contact customer service.
Switch off the device and let all
the air escape.
Contact customer service.
Contact customer service.
Switch off the device and let all
the air escape.
Change the setting of the
nozzles.
Let all air escape.
Set the correct salt content.
See section "Technical data".

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis