Herunterladen Inhalt Inhalt Diese Seite drucken

GM-Racing Purple SX12 Gebrauchsanleitung Seite 19

Vorwärtsregler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Start Current START AMP
After 5s of throttle neutral position, the Start current is activ.
The Start current should be ajusted for max. Start speed. (Low wheel spin).
(Factory setting 200A)
POWERCURVE
The Purple SX12 has 3 different power curves for different driving style and tracks.
0 = linear
1 = soft (exponential -)
2 = hard (exponential +) for stock racing
3-9 = hard
FREQUENCY
The digital high frequency of the speed controller gives you a high efficiency and also a high motor life
time. A higher frequency gives you a softer feeling and a less motor commutator burning. A lower
frequency keeps your speed controller cooler. For this reason the SX12 has a new variable frequency,
which chooses the best frequency dependent on the current. This gives you a better feeling, a higher
motor life time and a cooler speed controller.
New are the adjustments 1, 3, 5, 7 and 9 with current limiter, which regulates the current and not only
the pulse width. This gives you the same feeling for the car with a full battery and the possibility for
faster lap times at the beginning of the heat. You can adjust your personal feeling with the current limiter
(AMP LIMIT), the POWERCURVE and the TURBO, also dependent on the track condition and the grip.
You may adjust the AMP LIMIT between 80 and 200A.
The SX12 has a hardware (PWM) and a software PWM (KHZ). The software PWM (KHZ) does cause
less glitches in the receiver.
(Factory setting = 5= variable frequency 1-4KHZ+LIM)
Frequency
Display
GMVIS-Commander V2001-V2003
Variable PWM 0,5-8KHZ
NORMAL M NO BRK LOW F
Variable PWM+LIM 0,5-8K NORMAL M WITH BRK LOW F
PWM 2kHz
NORMAL M WITH BRK+R LOWF
PWM+LIM 2KHZ
BRUSHL M NO BRAKE HIGH F
Variable KHZ 1-4KHZ
BRUSHL M WITH BRK HIGH F
Variable KHZ+LIM 1-4KHZ BRUSHL M WITH BRK+R HIGH F
2KHZ
NORMAL M NO BRAKE HIGH F
2KHZ+LIM
NORMAL M WITH BRK HIGH F
1KHZ
NORMAL M WITH BRK+R HIGH F
1KHZ+LIM
BRUSHL M WITH BRK+R LOW F
V2004
V2005
NORMAL M WITH BRK 1KHZ
0
NORMAL M WITH BRK 1PWM
1
NORMAL M WITH BRK 2KHZ
2
BRUSHL M NO BRK HIGH F
3
BRUSHL M WITH BRK HIGH F
4
BRUSHL M WITH BRK+R HIGH F 5
NORMAL M WITH BRK 4KHZ
6
NORMAL M WITH BRK 4PWM
7
NORMAL M BRK+LIM 4KHZ
8
NORMAL M BRK+LIM 4PWM
9
19

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2838.hPurple sx12w2838

Inhaltsverzeichnis