Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Related Information On Taking Out Of Operation And Removal; Liability And Exclusion Of Liability - Elektror HRD Serie Betriebs- Und Montageanleitung

Hochdruckventilator
Vorschau ausblenden Andere Handbücher für HRD Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating and assembly instructions HRD
Minimum ball bearing service
Devices
life
motor shaft
HRD range
Ball bearing change recommendation
- Prior to reaching the minimum service life
- 30 months following delivery at the latest
- Check after 6 months' storage time; change if necessary
5.2 Seals and radial shaft sealing rings
Sealing elements and shaft sealing rings must, for safety rea-
sons, always be replaced after maintenance work involving
opening, removing or otherwise modifying sealing elements.
5.3 Micro-fi lters
The degree of clogging of the fi lter mats must be checked at
regular intervals in dependence on the conditions of use or
ambient conditions and any applicable environmental protec-
tion guidelines. This means that the user is responsible for
ensuring that the fi lters are permeable.
5.4 V-belt (in appliances supplied complete with V-belt
drive)
The minimum service life of the V-belt in use is 25,000 hours.
The V-belt tension must be checked after approximately
5,000 operating hours (refer to label for belt tension values
and setting values). New V-belts must be checked after a
running-in period of 2 hours and retensioned if necessary
(data see chapter 11 technical specifi cations).
Sa
dg
Checking and retensioning the V-belt
The item numbers given in brackets refer to the replacement
part drawing. Setting values: see label on the support fl ange
plate (59) respectively on the blower base (11).
Replacing/retensioning the V-belt:
• Remove the grating (55) or belt guard (27).
• Undo the hexagon bolt (60) or tensioning bolt on the
motor tensioning rail (43).
• Undo the hexagon bolt (58) or tensioning bolt on the
motor tensioning rail (43).
• Move the motor including support fl ange plate towards the
support fl ange housing.
• Remove the faulty V-belt (26).
• Check the V-belt pulleys
(they must be free from burrs, rust and dirt).
www.elektror.com
Horizontal
Vertical motor
shaft
22.000
11.000
hours
hours
f
dk
• Fit the new V-belt loosely by hand.
• Pay attention to exact alignment of the V-belt pulleys.
• Set the belt tension as per the label using a hexagon
bolt (58).
• Tighten the hexagon bolt (60) or fi xing bolt on the motor
tensioning rail (43).
• Attach the grating (55) or belt guard (27).
You will fi nd the data applicable to your appliance with V-
belt drive indicated on the label affi xed to the support fl ange
plate. They are also tabulated in section 11 of these Operat-
ing and Assembly Instructions.
5.5 Cleaning
There is a high risk of injury on the inside of the device due to
rotating parts during operation. Decommission the device in
all cases and wait until all moving parts have stopped before
opening, reaching in or inserting tools into the device. Secure
the device reliably against it being accidentally restarted dur-
ing the entire period.
Also make sure that no other dangerous situation can arise
when restarting after a standstill, e.g. as a result of a power
failure or blockages.
Cleaning or maintenance must not lead to damage or modi-
fi cations to the device and its components that would infl u-
ence safety or health protection and, for example, impair the
balanced state of the impeller.
When starting up the blower, make sure that all tools or other
foreign objects have been removed from inside the device
and that all covers and protective grilles have been attached
correctly.
6 SAFETY RELATED INFORMATION
ON TAKING OUT OF OPERATION AND
REMOVAL
The disconnection of all electrical connections and any other
electrical work in connection with decommissioning must
only be carried out by a qualifi ed electrician.
The device should be dismantled only when all rotating parts
have come to a standstill and cannot be restarted.
The guidelines set out in 2.1 Transport and Handling must be
observed when dismantling and removing it.
Treat the device as industrial waste when disposing of it.
The device parts are made of recyclable material, such as
aluminium, (stainless) steel, copper and plastic. However,
there are components that need special treatment (e.g. fre-
quency converters). The statutory national and local disposal
and recycling regulations must be observed.
7 LIABILITY AND EXCLUSION OF
LIABILITY
The owner shall bear the responsibility for the correct use of
the device.
Elektror shall not accept any liability for any use of its prod-
ucts and components which is contrary to their intended use.
This shall also apply in particular to use in special applica-
tions and under operating conditions that have not been spe-
cifi cally agreed with Elektror.
Elektror shall not accept any liability for any modifi cations or
alterations to the device or accessories supplied.
Likewise, Elektror shall not be liable for improper, delayed,
neglected maintenance. Neither shall it be liable for any
cleaning and repair work not carried out by qualifi ed Elektror
specialists, nor for the possible consequences.