Immediate inspection and maintenance:
When vibration and oscillation occurs, reduced air capacity.
EN
Note!
Repairs must be carried out only by the manufac-
turer. We will assume no liability where repairs,
modifi cations or exchanging of parts has been
carried out by a third party.

5.1 Ball bearings

Note!
The fans from Elektror are equipped with sealed
deep groove ball bearings, which do not require
relubrication.
Note!
Check the ball bearings during servicing and
prior to recommissioning.
Operation is only permitted with fl awless ball
bearings!
Note!
In the event of frequently starting up and shutting
down, premature replacement of the bearings
will be required. Determining the time for repla-
cing the bearings is the sole responsibility of the
maintenance and servicing personnel, who must
make a safety judgement.
Devices
SVD range
Ball bearing change recommendation
- Prior to reaching the minimum service life
- 30 months following delivery at the latest
- Check after 6 months' storage time; change if necessary
5.2 Sealings and radial shaft sealing rings
For safety reasons, sealing components and radial shaft
sealing rings are to be replaced at least on every occasion
when maintenance involves opening, removing or altering
sealing elements in some other way.
5.3 Fine fi lters
The degree of soiling of the fi lter mats must be checked at
regular intervals, as appropriate to the environmental/de-
ployment conditions and, where applicable, environmental
protection requirements. That is, the owner must ensure that
fi lters are permeable.
5.4 Cleaning
There is a high risk of injury on the inside of the device due to
rotating parts during operation. Decommission the device in
all cases and wait until all moving parts have stopped before
opening, reaching in or inserting tools into the device.
Secure the device reliably against it being accidentally re-
started during the entire period.
Also make sure that no other dangerous situation can arise
when restarting after a standstill, e.g. as a result of a power
failure or blockages.
18
Minimum ball bearing service
life
Horizontal
Vertical motor
motor shaft
shaft
22.000
11.000
Hours
Hours
Operating and assembly instructions SVD
Cleaning or maintenance must not lead to damage or modi-
fi cations to the device and its components that would infl u-
ence safety or health protection and, for example, impair the
balanced state of the impeller.
When starting up the blower, make sure that all tools or other
foreign objects have been removed from inside the device
and that all covers and protective grilles have been attached
correctly.
6 SAFETY RELATED INFORMATION
ON TAKING OUT OF OPERATION AND
REMOVAL
The disconnection of all electrical connections and any other
electrical work in connection with decommissioning must
only be carried out by a qualifi ed electrician.
The device should be dismantled only when all rotating parts
have come to a standstill and cannot be restarted.
The guidelines set out in 2.1 Transport and Handling must be
observed when dismantling and removing it.
Treat the device as industrial waste when disposing of it.
The device parts are made of recyclable material, such as
aluminium, (stainless) steel, copper and plastic. However,
there are components that need special treatment (e.g. fre-
quency converters). The statutory national and local disposal
and recycling regulations must be observed.
7 LIABILITY AND EXCLUSION OF
LIABILITY
The owner shall bear the responsibility for the correct use of
the device.
Elektror shall not accept any liability for any use of its prod-
ucts and components which is contrary to their intended use.
This shall also apply in particular to use in special applica-
tions and under operating conditions that have not been spe-
cifi cally agreed with Elektror.
Elektror shall not accept any liability for any modifi cations or
alterations to the device or accessories supplied.
Likewise, Elektror shall not be liable for improper, delayed,
neglected maintenance. Neither shall it be liable for any
cleaning and repair work not carried out by qualifi ed Elektror
specialists, nor for the possible consequences.
www.elektror.com