The recorded data sets can be called up in history mode or transferred to
MAX./MIN VALUES AND THE CURRENT DEW POINT in the selected
channel:
Press OK/MAX/MIN button in normal mode.
MAX appears in the display and the highest humidity is
displayed.
Press the button again.
The highest temperature is displayed.
Press OK/MAX/MIN button again.
MIN appears in the display and the lowest humidity is
displayed.
Press the button again.
The lowest temperature is displayed
Press the button again.
DEW appears in the display.
The current dew point is displayed.
The time and date when the respective value was determined
are also displayed.
The corresponding channel number is shown on the channel
display, and the assigned name or the serial number of an
entered transmitter is displayed.
To clear the recorded max.min.-values, please press and
hold OK/MAX/MIN button for three seconds in any mode.
The max./min. values will be deleted for all channels.
The display shows the current temperature and humidity at
all channels.
Max./min. values are not recorded in a data set.
Only the current max./min. values are displayed in the PC software.
ALARM SETTING MODE:
Press and hold the ALM button for the three seconds.
HIGH AL RH for the selected channel appears in the display.
The upper alarm limit for the humidity is flashing.
With the ALM button you can select one possible alarm limit
after the other:
a PC using the USB wireless transceiver.