Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS C-60 Serie Handbuch Seite 75

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C60_1-029_0108_en.p65
73
Dimensions, weight
Operating conditions
Connection type
Enclosure
Electrical
connections
74
Electrical
Connections
(continued)
Function Displays
74
E
BIS C-6021
Technical Data
Housing
Dimensions
Weight
Ambient temperature
Integral connector X1
Integral connector Head 1, Head 2
Round connector for X2
Round connector for X3
Integral connector X4
Protection class
Supply voltage V
S
Ripple
Current draw
Connections for supply voltage V
with installation remote bus
with remote bus
Output X2, input X3, I
B
NTER
US
Head 1, Head 2, Read/Write Head
BIS C-6021
Technical Data
Digital input X1 (+IN, –IN)
Control voltage active
Control voltage inactive
Input current at 24 V
Delay time, typ
Service interface X4
BIS operating states
LED red / green
(LED in housing)
LED green / yellow
LED green / yellow
I
B
state
LED green
NTER
US
(LED on side
LED green
of housing)
LED green
LED yellow
The CE-Mark is your assurance that our products are in conformance with the
EC-Guideline
89/336/EEC (EMC-Guideline)
and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for
Testing of Electromagnetic Compatibility, has confirmed that Balluff products meet the
EMC requirements of the Generic Standard
EN 50081-2 (Emission) and EN 50082-2 (Noise Immunity).
Metal
190 x 120 x 60 mm
820 g
0 °C to +60 °C
5-pin (male)
4-pin (male)
9-pin (female)
9-pin (male)
4-pin (male)
IP 65 (when connected)
DC 24 V ± 20 %
≤ 10 %
≤ 400 mA
S
at I
B
input X3, output X2
NTER
US
at input X1
serial interface for remote bus station,
Ident-No. 03, 16 bytes IN, 16 bytes OUT
(bei Modus BIS C-621: 8 Byte IN, 8 Byte OUT)
via integrated adapter with 2 x connectors
for all read/write heads BIS C-3_ _
with 4-pin connector (female),
excluding BIS C-350 and BIS C-352
galvanically isolated (optocoupler)
4 V to 40 V
1.5 V to –40 V
11 mA
5 ms
RS 232
Ready / Bus active
CT1 Present / Operating
CT2 Present / Operating
Reset
Cable Check
Bus active
Remotebus Disable
E
73

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis c-6001Bis c-6021

Inhaltsverzeichnis