Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS C-60 Serie Handbuch Seite 48

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C60_1-029_0108_en.p65
19
Description of
Output Buffer
(continued)
Please note the
basic procedure on
15 and 30...34
and the examples on
pages
35...47.
20
Description of
Output Buffer
(continued)
Please note the
basic procedure on
15 and 30...34
and the examples on
pages
35...47.
20
E
Function Description
Output buffer, configuration and explanation
Sub-
Meaning
Function Description
address
01
Command designator
Hex
00
No command present
Hex
01
Read code tag
Hex
02
Write to code tag
Hex
04
Configure processor
Hex
05
Read configuration data
Hex
06
Store program in the EEPROM for the Mixed Data Access
H
EX
function
07
Store the start address for the Auto-Read function in the EEPROM
H
EX
08
Initialize code tag
Hex
09
Save monitoring of code tag initialization in EEPROM
Hex
0A
Save split address for dividing the code tag into an area having
Hex
memory optimization in EEPROM
21
Read code tag using Mixed Data Access function (corresponding
H
EX
to the program stored in the EEPROM)
22
Write to code tag using the Mixed Data Access function
H
EX
(corresponding to the program stored in the EEPROM)
or
Configuration 1st byte
00
Default value (factory setting).
Hex
Changes depending on the configuration.
or:
Initialization data
or:
Data
for writing to the code tag
or:
Program data
for writing to the EEPROM.
(continued next )
Function Description
Output buffer, configuration and explanation
Sub-
Meaning
Function Description
address
02
Start address
Address at which reading from or writing to the code tag begins.
Hex
(Low Byte)
(The Low Byte includes the address range from 0 to 255).
or:
Program No.
Number of the program to be stored in the EEPROM in
conjunction with command ID 06
function.
or:
Program No.
Number of the program stored in the EEPROM for read or write
operations in conjunction with command ID 22
Mixed Data Access function.
or
Configuration 2nd byte
80
Default value (factory setting)
Hex
Changes depending on the configuration.
or:
Initialization data
or:
Data
for writing to the code tag
or:
Program data
for writing to the EEPROM.
or:
Parametering data for writing to the EEPROM.
(continued next )
E
19
for Mixed Data Access
Hex
or 22
for the
Hex
Hex

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bis c-6001Bis c-6021

Inhaltsverzeichnis